Why Deye? Because Deye is more than just a hybrid inverter: it offers full asymmetry management, a built-in EPS unit, and a smart meter without the need for additional accessories. As an open system, it works with various batteries, generators, and even multiple inverters, making it designable with fewer limitations and greater flexibility than many other manufacturers' systems.
Core Operational Functions and Capabilities
100% asymmetric phase load
One of the most important advantages of Deye inverters is their support for fully, 100% asymmetrical phase loading.
This means that the device can flexibly distribute the power of the three phases – it is not necessary to load each phase equally.
- The system can deliver a significant part of its power on even a single phase.
- The other phases can be minimally loaded if there is no consumption there.
- It does not require traditional, fixed symmetrical load distribution.
Operational limits may vary depending on the type, but the system is fundamentally designed to handle varying loads flexibly and without restrictions.
Fast EPS / Backup switching (≈4 ms)
In the event of a power outage, the system disconnects from the grid within a few milliseconds and immediately provides backup power to designated consumers. The transfer is so fast that it does not cause any noticeable interruption in the operation of most devices.
This function is particularly important in places where continuous operation is required or where sensitive devices are in use. The rapid transfer provides stability and increased safety in the event of an unexpected power outage.
LV and HV Battery Compatibility
The system supports the use of both 48 V (LV) and high-voltage (HV) batteries. LV solutions offer a wide range of battery choices and simple setup options, while HV systems enable higher charging and discharging power.
The choice between different battery types can be fully adapted to the user's needs, whether for smaller household storage or larger energy capacity systems. Compatibility makes installation and future expansion flexible.
Managing multiple energy sources
The system is capable of receiving multiple external energy sources, so it can work not only with solar panels, but also with wind generators or even diesel generators (depending on the model).
- Automatic generator connection is possible.
- Provides stable operation even in island mode.
- Suitable for areas affected by grid disturbances.
This is particularly practical in locations where the grid is unreliable or where a backup power source is needed.
Additional features
Choose the right Deye inverter type
Single-phase Deye hybrid inverters
Deye single-phase hybrid inverters can be used in buildings where a single-phase grid connection is available and no expansion to three-phase is planned. In Hungary, a maximum of approximately 2.5 kW of power can be fed back into the grid on a single-phase network. An inverter with a higher output than this cannot be connected to the grid on a single-phase connection; in such cases, it can only be operated off-grid.
The devices are compatible with 48V (low voltage) batteries and have an EPS / Backup output that can provide power to selected consumers in the event of a power outage. The built-in smart meter allows for real-time monitoring and control of production and consumption.
- 48V (LV) battery compatibility
- EPS / Backup operation in case of power outage
- Can be used with a single-phase network
3-Phase Deye Hybrid Inverters (LV)
The 3-phase Low Voltage (LV) Deye hybrid inverters can be used for asymmetric hybrid systems connected to a three-phase grid. The inverters support 100% asymmetric phase load, allowing different loads to be served on the three phases. The devices operate with 48V (low voltage) batteries and provide broad battery compatibility, provided that the connected unit meets the specified voltage range and BMS communication requirements.
The inverters are equipped with an EPS / Backup output, which ensures the supply of selected consumers in case of a power outage. Real-time monitoring and control are available through a built-in smart meter.
- 48V (LV) battery compatibility
- Asymmetric phase load
- EPS / Backup operation in case of power outage
3-Phase Deye Hybrid Inverters (HV)
3-phase High Voltage (HV) Deye hybrid inverters can be used in systems where higher power demand or three-phase load distribution is required. The devices support asymmetrical phase loads, so the three phases can operate with different loads.
Only high voltage (HV) batteries can be connected to these inverters; they are not compatible with 48V (LV) batteries. The supported battery voltage range is typically 160–800V, which allows for greater charging and discharging power with lower current and less loss. The inverter has an EPS / Backup output for power outages and is suitable for parallel operation of multiple inverters.
- 160-800V (HV) battery compatibility
- Asymmetrical phase load
- EPS / Backup operation in case of power outage
Deye All-in-One Hybrid System
The Deye GB-S5K–25K-EU is an All-in-One energy storage system based on a three-phase, asymmetrical hybrid inverter, which forms a complete unit with the GB series high-voltage (HV) batteries. This inverter is not a standalone product; it requires GB-LM4.0-HV battery modules and the GB-LB-BASE control and support unit for operation. The system thus manages solar production, the battery, and grid/off-grid operation as a single unit.
The power range is 5–25 kW, and up to 10 units can be paralleled within the system, allowing the system capacity to reach 250 kW.
The system supports 100% asymmetrical phase load and is suitable for diesel generator integration. The wide operating temperature range also allows for outdoor installation.
Mandatory System Components
-
GB-LM4.0-HV battery modules (min. 2, max. 6 per stack)
- GB-LB-BASE control and support unit
- All-in-One design → inverter + battery + controller
- Asymmetric phase load
- UPS / Backup operation in case of power outage
Do you have a question?
Do you have questions about Deye inverters? Contact us, we'll be happy to help.
Are Deye inverters capable of asymmetric three-phase operation?
Are Deye inverters capable of asymmetric three-phase operation?
Yes. Deye hybrid inverters are specifically designed to handle three-phase unbalanced loads, with a phase shift of up to 50%, and are capable of delivering full rated power even under such conditions. This means that it is not necessary to distribute consumption evenly among the phases: the inverter supplies more power to the phase where there is actual demand.
Furthermore, it can also power three-phase motors in off-grid mode, provided there is adequate battery and inverter power, which is more limited or not possible with other manufacturers.
What is the self-consumption of a Deye inverter in off-grid mode?
What is the self-consumption of a Deye inverter in off-grid mode?
When operating off-grid, the inverter consumes approximately 60–100 W. This energy is supplied from the power generated by the solar panels or from the battery. Consequently, there may be a slight difference of a few percent between the production values shown on the monitoring interface and the actual data displayed. This is a normal phenomenon and does not indicate a system fault.
How accurate is the Deye monitoring system?
How accurate is the Deye monitoring system?
Deye currently uses a third-party monitoring system (SolarMAN), which means there may be an approximately 4–5% inaccuracy in real-time data compared to the value shown on the display. However, daily and long-term statistical graphs are sufficiently accurate, and the manufacturer is continuously developing the monitoring system. In short: some discrepancies may occur with real-time data, but the system is reliable at a statistical level.
Which optimizers are compatible with Deye?
Which optimizers are compatible with Deye?
Deye inverters are compatible with Tigo optimizers, which can provide partial or full panel optimization and shade management. Tigo is a universal alternative and is easier to install as it does not require a separate communication device.
Among Deye's own optimizers:
-
XL02-A: basic optimizer function for shaded or differently oriented panels,
does not provide per-panel monitoring. -
XL02-B: also supports per-panel monitoring,
and requires a concentrator (data collector / communication hub) for operation.
Optimizers from other manufacturers with closed systems (e.g., SolarEdge or Huawei) are not compatible with Deye inverters.
Do I need a permit for Deye if I only use the backup output?
Do I need a permit for Deye if I only use the backup output?
Yes. In Hungary, every grid-tied inverter requires a permit, even if feed-in is disabled in the settings. A permit is not required if the system operates in true off-grid mode, meaning there is no grid connection.
Consumers connected to the backup output always receive power through the inverter, and in the event of a power outage, the device disconnects from the grid.
What is the switchover time in case of a power outage?
What is the switchover time in case of a power outage?
The transfer time is approximately 4 ms, which is fast enough for most household and IT consumers to continue operating without interruption. During transfer, the inverter briefly uses the battery for stabilization, thus the presence of a battery is a prerequisite for hybrid operation.
How do warranty and service work?
How do warranty and service work?
When an error is reported, the manufacturer performs remote diagnostics based on the inverter's serial number or monitoring connection. Depending on the type of repair:
- modular component replacements are possible (e.g., motherboard, IGBT),
- in case of a more serious problem, a full inverter replacement is carried out by the factory.
Warranty communication with the manufacturer takes place via direct channels (e.g., WeChat), but in the case of an authorized dealer, these steps can be delegated to them.
What external protections are required for the warranty?
What external protections are required for the warranty?
The manufacturer has no mandatory protection requirements, but recommendations are included (DC fuse, DC and AC side surge protection).
The inverter has built-in T3 surge protection, which provides protection against minor overvoltages, but in a lightning protection environment, additional protection is recommended.
Can lead-acid or deep-cycle batteries also be used?
Can lead-acid or deep-cycle batteries also be used?
Yes. Depending on the model, Deye inverters support both low and high voltage batteries.
Low Voltage (LV) hybrid models work with 48 V batteries, and with proper parameterization, lead-acid, AGM, GEL, or LiFePO₄ deep cycle batteries can be used. For these, the charging and discharging voltage limits, as well as the current limit, must be set manually.
High Voltage (HV) hybrid models support high-voltage (typically in the 150–800 V range) lithium batteries, which require BMS communication, and traditional 48 V or lead-acid units cannot be used with them.